LTD5600A High Frequency Radiography & Fluoroscopy Digital X ray System (630mA)
Function
gastrointestinal fluoroscopy/radiography, gastrointestinal examination, chest radiography, head and whole body bone radiography
gastrography, Esophagography, Myelography, Arthrography, cholangiography, bronchography, venography, angiography, urography, hysterosalpingography, Pediatric Radiology, treat application of several intervention radiology
Feature
1. base the optimization principle to produce, excellent config of whole system, satisfy clinical personalized requirement
2.latest technology of high frequency mainframe, digital image collection, gain the high quality image easily
3. show human-machine interface directly, excellent operation system, make man-machine conversation more conveniently and easy to understand multiple safety control, make the image quality and radiation dose to achieve organic balance
4.strong function of digital image processing, overall compatible with DICOM network application
The unit is available for medical teaching, research, medical units for gastrointestinal X-ray spot film photography, remote control compartment, fluoroscopy and other Traumatic Radiography etc of X-ray routine examination, Can be used for gastrointestinal imaging, cholangiography, Urinary tract imaging and Deep vein imaging and other imagings ; Can used for fluoroscopy of esophagus, breast, gastrointestine, Abdomen and limbs and spot film photography; Can do the operation of Fracture reduction and Taking foreign body from in vivo .
Main Specifications
Item | Content | Technical parameter |
Power supply | Voltage | 380V±38V |
Frequency | 50Hz±1Hz |
Capacity | ≥65kVA |
internal resistor | ≤0.17Ω |
Digital X-ray high voltage system (import high-frequency generator ) | | Power Output | 50KW |
photography | Tube Voltage | 40kv—150kv step regulation |
Tube Current | 10mA—630mA step regulation |
Exposure time | 1.0s—6300ms step regulation |
Control interface | Touched LCD |
fluoroscopy | Tube Voltage | 40kv—110kv step:2kv continuous regulation |
Tube Current | 0.5mA—6mA continuous regulation |
Automatic brightness for fluoroscopy IBS | Automatic brightness tracking,multiple settings beforehand |
Digital Controlled X-ray Tube (Toshiba, Japanese) | Model | E7884X |
Tube Focus:Large Focus/Small Focus | 1.2mm /0.6mm |
Input Power | Large focus: 50kW small focus: 20kW |
thermal capacity | 300KHU |
Rotary anode speed | 2800rpm |
Micro-computer control digital tube remote diagnostic table | Material of the tabletop | high strength,low absorb carbon fiber |
Rotation of the table | 90°~0°~-25° |
Transverse travel of table | ±110mm |
Longitudinal travel of the photography holder and film spot device | ≥720mm |
X-ray Focus—film gauge | 1100 mm—1500 mm |
Rotating foot plate | ±360° rotation |
Full film photography size | 8"×10"—14"×17" |
Dividing method for spot film | Full film, half dividing, three parts dividing, four parts dividing |
Control method for diagnostic table | Remote,table control,frequency conversion soft starting and stopping |
beam limiter | Electric Multi-leaf |
Voice interaction | Two-way microphone system |
fixed bucky device for table | Grid density: 103L/INCH, Grid ratio: 10:1,focusing distance: 120cm,fixed type: 15"×18" |
Digital Image TV System | Image Intensifier | TOSHIBA (9″) Image Intensifier |
high resolution CCD(digital cameras) | ultra-low-light,standard 470,000 pixel |
Monitor | 14"medical high definition monitor, horizontal central resolution ratio :1000 lines,fringe: 800 lines,video bandwidth: 12.5MHz,50bit,image number/second: 25 frame |
Digital Picture Processing System (CCUSentinel) | High definition line by line output mode, 8 level noise reduction,store 8 image;LIH(freeze the last frame),the image can be turned vertically and horizontally,positive and negative image;OSD(monitor show) |